Saturday , 14 December 2024
Breaking News

อุปกรณ์วัด Tube Test (Heating block NANOCOLOR® VARIO C2)

อุปกรณ์วัด Tube Test (Heating block NANOCOLOR® VARIO C2)

Heating block NANOCOLOR® VARIO C2
Heating block of the future
Be safe
 
Constant digestion conditions
•  High temperature stability
•  Electronic overheating protection
•  Graphic display of heating curves
Maximum safety for the user
•  Extra strong safety covers as contact
protection (10 mm, replaceable)
on the heating block surface
•  Lockable protective lids
•  Display alert in case of open protective lid
 
Meet specifications
 
Internal quality control according to ISO 9001
•  In conformance with requirements of internal quality control (IQC)
•  Comply with demands of supervisors and authorities
•  Heating curves to check temperature stability
•  Electronic temperature control and fully automatic calibration with the
NANOCOLOR® T-Set (REF 919 917)

 •  Comfortable data transfer via USB or serial interface RS 232
•  Easy generation of quality certificates in accordance to GLP with the
NANOCOLOR® T-Set software
 
NANOCOLOR® T-Set
Automatic temperature control and calibration of the heating blocks
•  Connect the RS 232 plug of the T-Set to the heating block
•  Place the temperature sensor into the small bore located on the safety cover
Select „T-Set“ in the menu Select the respective program Start the program
 
Universal thermometer for external temperature measurements
•  Connect the RS 232 plug of the T-Set to the heating block
•  Dip the temperature sensor into the respective sample solution
•  The temperature is displayed in the heating block’s display
Save time
 
Intuitive operation
•  Convenient input via icons
•  Quick and easy selection of heating programs
Start screen   Temperature selection   Time selection     Program start
 
Time-saving procedures
•  Extremely short warm-up times (from 20 to 160 °C in just 10 minutes)
•  High-speed COD, total-Nitrogen, total-Phosphorous and
total-Metals in just 30 minutes
Self-explanatory user guidance
•  User-friendly, bright touch screen
•  Operation without time-consuming training
 
Experience flexibility
 
The ideal size for any purpose
NANOCOLOR® VARIO C2: Simultaneous digestion of up to 12 samples
Standard programs and easy programming
•  5 pre-programmed temperatures 70 / 100 / 120 / 148 / 160 °C
•  4 pre-programmed heating times 30 min / 60 min / 120 min / cont.
•  7 free memory locations between 40 -160 °C (1 °C increments)
•  8 free memory locations between 0h:01min – 9h:59min (1min increments)
 
Suitable for all NANOCOLOR® digestion methods
Application Temperature Time
COD (DIN ISO 15705) 148 °C 120 min
High-speed COD 160 °C 30 min
TOC 120 °C 120 min
total-Nitrogen 120 °C 30 min
total-Phosphorous 120 °C 30 min
Organic acids 100 °C 10 min
total-Metals (Cadmium, Chromate, Iron, Cobalt, Copper, Nickel, Zinc) 120 °C 30 min
AOX 120 °C 30 min
Hydrocarbons 148 °C 120 min
Programmable, user-defined programs 40 – 160 °C 0h:01min – 9h:59min
 
Technical Data
 
Instrument: NANOCOLOR® VARIO C2
Type: Programmable heating blocks for chemical-analytical digestions with 12 holes / for test tubes with 16 mm OD (outer diameter) / integrated protective lids
Display: Coloured, backlit LCD touch screen
Operation: Display menu guidance via touch screen
Temperatures: 5 pre-programmed temperatures: 70 / 100 / 120 / 148 / 160 °C
7 free memory locations for individual temperature settings
Temperature range: 40 – 160 °C (1 °C increments)
Temperature stability: ± 1 °C (according to DIN, EN, ISO and EPA methods)
Warm-up time: from 20 °C to 160 °C within 10 minutes
Heating times: 4 pre-programmed heating times: 30 min / 60 min / 120 min / cont.
8 free memory locations for individual heating times
Time range: 0h:01min – 9h:59min (increments 0h:01min)
Safety: Replaceable safety covers as contact protection
Lockable protective lids
Overheating protection
Interfaces: Bidirectional serial RS 232, USB A (master) and USB B (slave)
Analytical quality control: With NANOCOLOR® T-Set (REF 919 917)
optional fully automatic calibration and preparation of test certificates for instrument control and monitoring according to ISO 9001)
Update: Via internet and USB stick
Power supply: 110 – 230 V~, 50/60 Hz
Power consumption: 125/250 VA
Dimensions (B x T x H): 169 x 282 x 146 mm
Weight: approx. 2.0 kg
Marking: CE
Warranty: 2 years
These instruments conform to the following directives:
– 2006/95/EC – Low-Voltage Directive
– 2004/108/EC – EMV Directive
 
Ordering information
NANOCOLOR® VARIO C2
Heating block incl. protective lids, power line cord, USB cable, software-DVD, certificate and manual
REF 919 350
NANOCOLOR® T-Set
Electronic temperature sensor incl. software-DVD, certificate and manual

Quotation and Ordering
131 Thailand Science Park. Innovation Cluster 1 Building, Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. +6681-847-6768, +662-191-3928 Fax +662-191-3929 Mr.Thoniwadh +6685-811-4779, Ms.Nareerat +6685-814-9653
Email: info@highents.com

สนใจขอใบเสนอราคาและสั่งซื้อสินค้า
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1 ต. คลองหนึ่ง อ. คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟกซ์ 02-191-3929 คุณโทณิวัฒน์ 085-811-4779, คุณนารีรัตน์ 085-814-9653
Email : info@highents.com

REF 919 917
  •  

    >>> ขอใบเสนอราคาแบบออนไลน์ คลิก !!

  • Scroll To Top