อุปกรณ์กรอง Syringe Filter CHROMAFIL RC

RC

CHROMAFIL® RC  
Syringe filters with membrane of regenerated cellulose  
Features
Hydrophilic membrane with very low adsorption

For aqueous and organic – aqueous liquids, i.e. polar and medium polar sample solutions

Binding capacity for proteins 84 µg per 25 mm filter

 
 Ordering information · CHROMAFIL® Xtra
Regenerated cellulose syringe filters labeled for method validation and certification

Type Pore size Membrane   Standard pack BIG-BOX
  [µm] dia. [mm]   Filters/pack REF Filters/pack REF
RC-20/25 0.20 25 labeled 100 729230 400 729230.400
RC-45/25 0.45 25 labeled 100 729231 400 729231.400
 
 Ordering information · CHROMAFIL®
Color-coded regenerated cellulose syringe filters

Type Pore size Membrane Color code Standard pack BIG-BOX
  [µm] dia. [mm] top bottom Filters/pack REF Filters/pack REF
RC-20/15 MS 0.20 15 yellow blue 100 729036 800 729036.800
RC-45/15 MS 0.45 15 colorless blue 100 729037 800 729037.800
RC-20/25 0.20 25 yellow blue 100 729030 400 729030.400
RC-45/25 0.45 25 colorless blue 100 729031 400 729031.400
MS = minispike on filter exit
 CHROMAFIL® filter membranes  
Chemical compatibility of filter materials  
The following table lists the chemical compatibility of our CHROMAFIL® materials. The chemical compatibility depends on several parameters such as time, pressure, temperature and concentration. In most cases, CHROMAFIL® filters will have only short contact with a solvent.   In these cases they may be used despite of limited compatibility.
For example, a PTFE filter with PP housing does not liberate any UV-detectable substances during filtration of 5 mL THF, although PP shows only limited resistance towards THF.

 

Solvent Material
  MV CA RC PA PTFE H-PTFE PVDF PES PET GF PP
Acetaldehyde o   o
Acetic acid, 100 %
Acetone
Acetonitrile
Ammonia, 25 % o o
Benzene o   o
n-Butanol o
Cyclohexane o
Dichloromethane
Diethyl ether o o o
Dimethylformamide o
1,4-Dioxane o o
Ethanol
Ethyl acetate o
Ethylene glycol o o
Formic acid, 100 % o o
Hydrochloric acid, 30 %
Methanol
Nitric acid, 65 % o o o   o
Oxalic acid, 10 % aqueous  
Petroleum ether  

Quotation and Ordering
131 Thailand Science Park. Innovation Cluster 1 Building, Klong 1, Klong Luang, Pathumthani 12120 Thailand.
Tel. +6681-847-6768, +662-191-3928 Fax +662-191-3929 Mr.Thoniwadh +6685-811-4779, Ms.Nareerat +6685-814-9653
Email: info@highents.com

สนใจขอใบเสนอราคาและสั่งซื้อสินค้า
131 อุทยานวิทยาศาสตร์ประเทศไทย อาคารกลุ่มนวัตกรรม 1 ต. คลองหนึ่ง อ. คลองหลวง จ. ปทุมธานี 12120
โทร. 081-847-6768, 02-191-3928 แฟกซ์ 02-191-3929 คุณโทณิวัฒน์ 085-811-4779, คุณนารีรัตน์ 085-814-9653
Email : info@highents.com

  •  

    >>> ขอใบเสนอราคาแบบออนไลน์ คลิก !!

  • Scroll To Top